20% OFF shipping at thegrowthteam.biz on orders over $79 + up to 10% OFF products
thegrowthteam.biz
home > LRD07 - BIMETALLIC OVERLOAD Relay 600V 2.5A IEC > LRD07 - BIMETALLIC OVERLOAD Relay 600V 2.5A IEC
download picture
LRD07 - BIMETALLIC OVERLOAD Relay 600V 2.5A IECLRD07 TeSys LRD, thermal overload relay, 1. 6 to 2. 5 A, class 10A Authorized Square D Distributor **Beware of buying counterfeit electrical products** Looking for a product you don't see? Call our knowledgeable sales staff 800 347 0794 range TeSys product name TeSys LRD product or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D18 LC1D38 LC1D32 LC1D25 LC1D12 LC1D09
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

LRD07 - TeSys LRD, thermal overload relay, 1.6 to 2.5 A, class 10A

Authorized Square D Distributor **Beware of buying counterfeit electrical products** Looking for a product you don't see? Call our knowledgeable sales staff 800-347-0794


range
TeSys
product name
TeSys LRD
product or component type
Differential thermal overload relay
device short name
LRD
relay application
Motor protection
product compatibility
LC1D18
LC1D38
LC1D32
LC1D25
LC1D12
LC1D09
network type
DC
AC
thermal overload class
Class 10A conforming to IEC 60947-4-1
thermal protection adjustment range
1.6…2.5 A
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit: 600 V conforming to UL
Power circuit 690 V IEC 60947-4-1
Complementary
network frequency
0...400 Hz
mounting support
Plate, with specific accessories
Rail, with specific accessories
Under contactor
tripping threshold
1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
auxiliary contact composition
1 NO + 1 NC
[Ith] conventional free air thermal current
5 A signalling circuit
permissible current
3 A at 120 V AC-15 for signalling circuit
0.22 A 125 V DC-13 signalling circuit
[Ue] rated operational voltage
690 V AC 0...400 Hz power circuit IEC 60947-4-1
associated fuse rating
4 A gG for signalling circuit
4 A BS signalling circuit
[Uimp] rated impulse withstand voltage
6 kV
phase failure sensitivity
Tripping current 130 % of Ir on two phase, the last one at 0
control type
Red push-button stop
Blue push-button reset
temperature compensation
-4…140 °F (-20…60 °C)
connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) solid without cable end
tightening torque
Control circuit: 1.7 N.m - on screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
height
2.60 in (66 mm)
width
1.77 in (45 mm)
depth
2.76 in (70 mm)
Net Weight
0.27 lb(US) (0.124 kg)
Environment
protective treatment
TH conforming to IEC 60068
IP degree of protection
IP20 conforming to IEC 60529
ambient air temperature for operation
-4…140 °F (-20…60 °C) without derating IEC 60947-4-1
ambient air temperature for storage
-76…158 °F (-60…70 °C)
flame retardance
V1 UL 94
mechanical robustness
Vibrations6 Gn IEC 60068-2-6
Shocks15 Gn for 11 ms IEC 60068-2-7
dielectric strength
1.89 kV 50 Hz IEC 60947-1
standards
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
product certifications
IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
Ordering and shipping details
Category
22347 - CONTACTOR,D-LINE,OVERLOADS-NEW
Discount Schedule
I12
GTIN
00785901206743
Nbr. of units in pkg.
1
Package weight(Lbs)
0.32 lb(US) (0.15 kg)
Returnability
Yes
Country of origin
FR
Packing Units
Unit Type of Package 1
PCE
Package 1 Height
1.93 in (4.9 cm)
Package 1 width
3.03 in (7.7 cm)
Package 1 Length
3.46 in (8.8 cm)
Unit Type of Package 2
S02
Number of Units in Package 2
24
Package 2 Weight
8.05 lb(US) (3.653 kg)
Package 2 Height
5.91 in (15 cm)
Package 2 width
11.81 in (30 cm)
Package 2 Length
15.75 in (40 cm)
Unit Type of Package 3
P06
Number of Units in Package 3
384
Package 3 Weight
160.56 lb(US) (72.827 kg)
Package 3 Height
31.50 in (80 cm)
Package 3 width
31.50 in (80 cm)
Package 3 Length
23.62 in (60 cm)
Offer Sustainability
Sustainable offer status
Green Premium product
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Contractual warranty
Warranty
18 months

 

LRD07 - BIMETALLIC OVERLOAD Relay 600V 2.5A IEC

Item no : 71461014270
sold recently : Login >>
US$ 92.37
Pay in 4 interest-free payments of $23.09 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 20 - Jun 25

Enjoy 20% off shipping

US$ 92.37

1-11

US$ 83.13

12-35

US$ 64.66

36-59

US$ 55.42

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches